How to manage high purity sulfur hexafluoride cylinders?
Check whether the outer surface of the gas cylinder has defects and whether the safety accessories are complete. In case of doubt, conduct flaw detection. After each inflation, IAC510 infrared leak detector shall be used to check whether there is leakage of high-purity sulfur hexafluoride at the joint of valve body and cylinder body.
More than 30% of new gas cylinders shall be sampled for inspection. The filled high-purity sulfur hexafluoride shall have the manufacturer's analysis report and biological test certificate, and the inspection certificate shall be hung outside the cylinder.
The sulfur hexafluoride manufacturer shall prohibit gas cylinders from being close to heat sources, oil stains, etc., from being exposed to the sun or damped, and shall place them on the shelf with the marks facing outward. Hotline: 139-4929-0069.